进瓶故障
现象:瓶子推不进瓶盒,进瓶离合器动作,触动限位开关导致停机,进瓶故障指示灯亮。
原因:瓶盒内残留有玻璃碎片。
排除:此时推进杆由回程装置驱动向后退回,如果退回距离不够,还可以利用操作箱的按钮使其进一步退回,清除玻璃片,拧动旋钮使进瓶安全离合器复位,红灯灭,可重新开机。
出瓶故障
现象:出瓶接瓶或推 bottled by glass, out of bottle safety clutch open, trigger limit switch stop machine, out of bottle fault indicator red light.
Reason: Glass pieces or debris stuck, causing overload.
Elimination: Remove glass pieces or blocked bottles or debris, turn the handle to reset the out of bottle safety clutch, red light off, can be restarted.
驱动轴Ⅰ或Ⅱ、Ⅲ超载
Phenomenon: Force arm movement triggers travel switch to stop machine, drive shaft 1 or 2/3 overloading indicator red light.
Cause: ① Chain box motion occasionally encounters abnormal resistance and causes overload.
② Chain too loose or too tight.
Elimination:
- Hand main motor handwheel to restore protection device position and restart with red lights extinguished.
瓶底喷吹故障
Phenomenon: Bottle bottom blow-out fan failure; electrical failure indication red light on.
Cause: Blower motor overcurrent tripped off power supply.
Elimination: Electrical inspection by electrician.
破 bottles多
Phenomenon: Increased broken glass fragments in the wash tank during operation
as a result from an increase in temperature difference between different channels of washing liquid,
low quality bottles,
mechanical malfunction,
blockage at any part that may cause obstruction,
升温困难
Phenomenon : Steam pressure meets requirements but heating water temperature rises slowly
due to poor drainage of condensate water caused by long steam lines not well insulated
and excessive scale buildup on heat exchanger surfaces
瓶子不洁
Phenomenon : Many dirty bottles remain after washing cycle due to low temperatures for washing liquids
insufficient alkalinity levels in cleaning solutions,
excessive foam formation during wash cycle,
clogged spray nozzles,
difficult-to-wash materials inside containers before filling
喷射压力下降
Presenting symptoms include decreased spraying pressure with corresponding green color turning into red indicating problem through indicators on control panel
9 . 进入装置失灵
In case where the advancing mechanism fails without response
10 进入离合打滑
11 进入离合常见问题
12 入装设备运行缓慢